# Building automation and energy meters

> PLCGateway connects HVAC and building controllers with BACnet/IP and energy meters with Modbus, for building management and ISO 50001 energy management.

Building controllers from Siemens, Johnson Controls, Honeywell, Schneider Electric, Trane, Carrier and Distech speak BACnet/IP. PLCGateway discovers them, lists their objects with names and reads and writes values with priorities.

Energy meters and power analysers are usually connected with Modbus. With the HVAC and electrical symbols and the energy management module, PLCGateway shows the building, the plant and the energy flows in one system.

## Families and models

| Family | Models (examples) | Protocol |
|---|---|---|
| Siemens Desigo | PXC4, PXC5, PXC7, PXC Modular — BACnet/IP automation stations. | [BACnet/IP](https://plcgateway.com/protocols/bacnet.md) |
| Johnson Controls Metasys | NAE / SNE / SNC, FEC / CGM — BACnet/IP through the network engines and field controllers. | [BACnet/IP](https://plcgateway.com/protocols/bacnet.md) |
| Honeywell | WEBs, Spyder, CIPer — BACnet/IP controllers. | [BACnet/IP](https://plcgateway.com/protocols/bacnet.md) |
| Schneider Electric EcoStruxure Building | SpaceLogic AS-P, MP-C — BACnet/IP automation servers and controllers. | [BACnet/IP](https://plcgateway.com/protocols/bacnet.md) |
| Chillers, AHUs and VAV controllers | Trane Tracer SC+, Carrier i-Vu, Distech ECLYPSE — BACnet/IP controllers of chillers, air handling units and VAV systems. | [BACnet/IP](https://plcgateway.com/protocols/bacnet.md) |
| Energy meters and power analysers | Janitza UMG, Schneider PowerLogic PM5000, Siemens SENTRON PAC, Carlo Gavazzi EM — Modbus TCP, or Modbus RTU through a gateway. | [Modbus TCP / RTU](https://plcgateway.com/protocols/modbus.md) |

## Notes for commissioning

- Use Find devices to discover BACnet devices in the network.
- Select points from the object list with their names instead of typing instance numbers.
- Set a write priority that matches the building's priority concept.
- Add meters to energy management with their cost and CO2 factors.

## Questions and answers

### Can PLCGateway be a small building management system?

Yes: BACnet and Modbus connectivity, HVAC symbols, alarms, schedules through screens, history and energy management in one product.

### Is BACnet MS/TP supported?

Through a BACnet router to BACnet/IP.

### Which meters work?

Meters with Modbus TCP or Modbus RTU through a gateway, for example Janitza UMG, Schneider PowerLogic, Siemens SENTRON PAC and Carlo Gavazzi.

## Related controllers and devices

- [Protection relays, IEDs and RTUs](https://plcgateway.com/controllers/protection-relays.md)
- [Schneider Electric Modicon](https://plcgateway.com/controllers/schneider-electric.md)
- [Siemens SIMATIC](https://plcgateway.com/controllers/siemens.md)
- [All protocols](https://plcgateway.com/protocols.md)