Controllers

Protection relays, IEDs and RTUs

PLCGateway brings switchgear, protection and energy data into SCADA and energy management with IEC 61850, DNP3 and IEC 60870-5-104.

Industrial substations and utilities use protection relays, bay controllers and RTUs with standard telecontrol protocols. PLCGateway connects them with IEC 61850 MMS, DNP3 or IEC 60870-5-104, depending on what the device offers.

Breaker positions, measurements, energy counters and alarms are shown on screens with the electrical symbols, logged for energy management and ISO 50001, and combined with production data in the same reports.

Families and models
Siemens SIPROTEC · SICAM · ABB Relion · RTU500 · SEL · GE Vernova Multilin · Schneider Electric Easergy

Families and models

FamilyModels (examples)Protocol
Siemens SIPROTEC · SICAMSIPROTEC 5, SIPROTEC 4, SICAM A8000
IEC 61850, DNP3 or IEC 104, depending on the device and its communication module.
IEC 61850 MMS
DNP3 (IEEE 1815)
IEC 60870-5-104
ABB Relion · RTU500REF615, RET620, REL670, RTU520 / RTU540
IEC 61850 and DNP3 on the relays; RTU500 also with IEC 104.
IEC 61850 MMS
DNP3 (IEEE 1815)
IEC 60870-5-104
SELSEL-751, SEL-787, SEL-411L, SEL-3530 RTAC
DNP3, and IEC 61850 on models with the IEC 61850 option.
DNP3 (IEEE 1815)
IEC 61850 MMS
GE Vernova MultilinUR series (D60, F60, T60), 8 series (850, 869)
IEC 61850 and DNP3, depending on the ordered options.
IEC 61850 MMS
DNP3 (IEEE 1815)
Schneider Electric EasergyMiCOM P40, Easergy P3, Sepam series 80
IEC 61850, DNP3 or IEC 104, depending on the model.
IEC 61850 MMS
DNP3 (IEEE 1815)
IEC 60870-5-104

Notes for commissioning

  • Clarify with the operator which protocol and point list may be used.
  • IEC 61850: browse the data model instead of searching the ICD file.
  • Use separate networks or VPNs for protection devices.
  • Draw breakers, transformers and feeders with the electrical symbols of the screen designer.

Questions and answers

Which protocol should I use?

IEC 61850 where the device offers it and its data model is wanted; DNP3 or IEC 104 where the utility or the RTU uses it.

Can operators switch breakers?

Yes, with controls over IEC 61850, DNP3 or IEC 104, protected by user roles, confirmations and PIN on the operator screens.

Is PLCGateway a replacement for a utility SCADA?

It is aimed at industrial sites and buildings: substation data together with production and energy, not the control centre of a grid operator.

Connect your machines

Tell us which controllers you run; we show you PLCGateway with your own addresses.

Product and model names are trademarks of their owners. They are named only to show which equipment the drivers communicate with; PLCGateway is not affiliated with these companies.